Shenzhen Xuming Electric Technology Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. Du Ado
  • Company Name : Shenzhen Xuming Electric Technology Co., Ltd.
  • Tel : 86-0755-81784915,13530371712
  • Fax : 86-0755-86322669
  • Address : Guangdong,Shenzhen,No.108 Xuming Industrial Zone,Baoshi West Road, Shiyan Town, Baoan District,Shenzhen,Guangdong,China
  • Country/Region : China
  • Zip : 518108

11KV 1600KVA Oil Filled Three phase Power Transformers

11KV 1600KVA Oil Filled Three phase Power Transformers
Product Detailed
Related Categories:Transformers
1.Low no-load loss&energy conservation 2.Low noise&environmental protection 3.Power Transformers 4.IP20 IP23 5.IEC ISO

1,11kV, S11 ,3 phase oil immersion power transformer 2,high efficiency, low loss 3,Low losses and Low Noise

 

Describtation of the product:

The three-phase oil-immersed distributing transformer applies new type insulating structure and makes short-circuit resistances strong. The iron core is made of high-quality cold-rolled silicon-steel plate. High-voltage winding group is made up of high-quality oxygen-free copper lines and it adopts multilayered drum type structure. All fasteners have been processed with special treatment to prevent them from loosening.

Standards

GB 1094.1-1996     GB 1094.2-1996    JB/T 10088-2004

GB 1094.3-2003     GB 1094.5-2003    GB/T10237-1988

GB/T 6451-1999     GB/T 7595-1987    JB/T 3837-1998

 

technical data:1) Rated Power: 30~2500kVA2)Rated HV: 6KV,6.3KV, 10KV, 10.5KV,11KV,15KV,20KV,22KV,33KV 35KV,36KV3)Rated LV: 0.4kV,0.415KV,0.38KV4)Phase No. :single or three;5)Rated frequency: 50Hzor 60 Hz;6)Vector group: Dyn11, Yyn0 or others;7)Short circuit impedance: 4%, 4.5% ,6% or others in accordance to client needs;8)Tapping voltage regulation type: off-load or on-load;9)Tapping range: +/-2*2.5% / 5%or others in according to client needs;10)Cooling type: oil nature, oil cooling

 

Performance Parameter List

Rated

capacity

(kVA)

Voltage combination and tap range

Connection

Group

No-load

loss

(W)

75oC load loss

 

(W)

No-load

current

(%)

Impedance

voltage

(%)

High

voltage

(kV)

Tap

(%)

Low

voltage

(kV)

10

6

6.3

6.6

10

10.5

11

±5

±2×2.5

0.4

0.69

Yyn0

Dyn11

Yzn11

55

310/325

2.80

4.0

20

70

480/500

2.50

30

100

600/630

2.30

50

130

870/910

2.00

63

150

1040/1090

1.90

80

180

1250/1310

1.90

100

200

1500/1580

1.80

125

240

1800/1890

1.70

160

280

2200/2310

1.60

200

340

2600/2730

1.50

250

400

3050/3200

1.40

315

480

3650/3830

1.40

400

570

4300/4520

1.30

500

680

5150/5410

1.20

630

810

6200

1.10

4.5

800

980

7500

1.00

1000

1150

10300

1.00

1250

1360

12000

0.90

1600

1640

14500

0.80

2000

2000

17400

0.70

5.0

2500

2400

20200

0.60

   3150

2800

24000

0.50

Note: 1. Load loss values above the oblique line in the table are applicable to the Yyn0 connection group, and the values below the oblique line are applicable to the Dyn11 or Yzn11 connection group. 

         2. The list shows main performance parameters of a three-phase duplex winding off-circuit-tap-changing distribution transformer. Customized transformers of different specification are available upon the demand of users.

11KV 1600KVA Oil Filled Three phase Power Transformers



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.